‘Star Trek: Strange New Worlds’ Pulled Off Something Better Than a Classic Zombie Story
‘Shuttle to Kenfori’ sidesteps the ‘Are we the real monsters?’ trope of zombie horror to deliver a perfectly ‘Trek’ message.
‘Shuttle to Kenfori’ sidesteps the ‘Are we the real monsters?’ trope of zombie horror to deliver a perfectly ‘Trek’ message.
The future of ‘Doctor Who’ may be up in the air, but fans can celebrate its past (and its upcoming spin-off) at this immersive experience.
3I/ATLAS is likely a comet from a faraway place. Or is it?
CVE-2025-6704 (CVSS score: 9.8) – An arbitrary file writing vulnerability in the Secure PDF eXchange (SPX) feature can lead
Successful exploitation of these vulnerabilities could result in information exposure, denial of service, or remote code execution.
Honeywell reports these vulnerabilities affect the following:
The Honeywell Experion PKS contains an uninitialized variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to communication channel manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service.
CVE-2025-2520 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
The Honeywell Experion PKS contains a memory buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to overread buffers, which could result in improper index validation against buffer borders, leading to remote code execution.
CVE-2025-2521 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H).
The Honeywell Experion PKS contains sensitive information in resource vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to communication channel manipulation, which could result in buffer reuse, which may cause incorrect system behavior.
CVE-2025-2522 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N).
The Honeywell Experion PKS contains an integer underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to communication channel manipulation, which could result in a failure during subtraction, allowing remote code execution.
CVE-2025-2523 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H).
The Honeywell Experion PKS contains a deployment of wrong handler vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to input data manipulation, which could result in incorrect handling of packets, leading to remote code execution.
CVE-2025-3946 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H).
The Honeywell Experion PKS contains an integer underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to input data manipulation, which could result in improper integer data value checking during subtraction, leading to a denial of service.
CVE-2025-3947 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H).
Positive Technologies reported these vulnerabilities to Honeywell.
Honeywell recommends updating Experion PKS R520.2 TCU9 Hot Fix 1 or R530 TCU3 Hot Fix 1. For more information, see the Security Notice.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
Successful exploitation of this vulnerability could allow an attacker to gain full administrative access to the device.
The following Network Thermostat product is affected:
The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the Local Area Network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat’s embedded web server and reset user credentials by manipulating specific elements of the embedded web interface.
CVE-2025-6260 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
A CVSS v4 score has also been calculated for CVE-2025-6260. A base score of 9.3 has been calculated; the CVSS vector string is (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).
Souvik Kandar reported this vulnerability to CISA.
Network Thermostat recommends users to update to the following (or newer) versions:
This update was applied automatically to reachable units, requiring no action from end users.
If end users would like their units behind firewalls to be updated, contact Network Thermostat at support@networkthermostat.com to coordinate an update.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
Successful exploitation of this vulnerability could allow an attacker to execute malicious code by getting setup-launcher to load a malicious DLL.
The following versions of Mitsubishi Electric CNC Series are affected:
Malicious code execution vulnerability via DLL hijacking due to Uncontrolled Search Path Element (CWE-427) exists in Flexera InstallShield used in multiple software tools and industrial IoT-related products for Mitsubishi Electric CNC Series.
CVE-2016-2542 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H).
Sahil Shah reported this vulnerability to Mitsubishi Electric.
The vulnerability is fixed in the following products and versions. Download and install the fixed version from the Mitsubishi Electric download site:
Note that there are no plans to release fixed versions for the following products:
For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends taking the following mitigations to minimize the risk of exploiting this vulnerability:
For more information, see Mitsubishi Electric 2025-008.
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity.
Armed with new data showing AI actually boosts search volume, the tech giant has turned a perceived threat into a powerful new weapon.